The MY2N-D2-GS DC24 is a relay manufactured by OMRON. Below are the factual specifications, descriptions, and features:

Specifications:

  • Model: MY2N-D2-GS DC24
  • Manufacturer: OMRON
  • Contact Configuration: 2 Form C (DPDT – Double Pole Double Throw)
  • Rated Load: 5A @ 250V AC, 5A @ 30V DC
  • Coil Voltage: 24V DC
  • Contact Resistance: ≤ 100mΩ
  • Insulation Resistance: ≥ 100MΩ (at 500V DC)
  • Dielectric Strength: 2,000V AC (50/60Hz for 1 min) between coil and contacts
  • Operate Time: ≤ 15ms
  • Release Time: ≤ 5ms
  • Mechanical Life: 10,000,000 operations
  • Electrical Life: 100,000 operations (at rated load)
  • Ambient Temperature Range: -40°C to +70°C
  • Weight: Approx. 15g

Descriptions:

  • A compact, high-performance General-Purpose Relay with PCB mounting.
  • Features gold-plated contacts for improved reliability in low-current applications.
  • Designed for automation, control systems, and industrial applications.

Features:

  • High Sensitivity: Low power consumption (360mW).
  • High Dielectric Strength: Ensures safety in high-voltage applications.
  • Compact Design: Space-saving PCB mountable relay.
  • Gold-Plated Contacts: Enhances durability and reduces contact resistance.
  • LED Indicator (Optional): Some variants include a built-in LED for coil status indication.

For exact dimensions and wiring diagrams, refer to the official OMRON datasheet.

# Technical Analysis of the MY2N-D2-GS DC24 Relay

## Practical Application Scenarios

The MY2N-D2-GS DC24 is a compact, high-performance electromechanical relay manufactured by OMRON, designed for 24V DC control applications. Its robust construction and reliable switching capabilities make it suitable for a variety of industrial and automation scenarios:

1. Industrial Control Systems – The relay is commonly used in PLC (Programmable Logic Controller) output modules to switch motors, solenoids, and actuators. Its high dielectric strength (2,500V AC) ensures stable operation in electrically noisy environments.

2. Automation Equipment – In automated assembly lines, the MY2N-D2-GS DC24 facilitates signal switching for sensors, conveyor belts, and robotic arms. Its dual-contact configuration (2 Form C contacts) allows for both NO (Normally Open) and NC (Normally Closed) operations, enhancing flexibility in circuit design.

3. HVAC Systems – The relay’s ability to handle resistive and inductive loads (up to 5A at 250V AC or 30V DC) makes it ideal for controlling compressors, fans, and heating elements in climate control systems.

4. Power Distribution Panels – Used in circuit protection and load switching, the relay ensures safe isolation between control and power circuits, minimizing the risk of electrical faults.

5. Test and Measurement Equipment – Precision switching requirements in lab instruments and diagnostic tools benefit from the relay’s low contact resistance (≤100mΩ) and high mechanical durability (10 million operations).

## Common Design-Phase Pitfalls and Avoidance Strategies

1. Inadequate Load Matching – Exceeding the relay’s rated current or voltage can lead to premature contact wear or welding.

  • Solution: Verify load characteristics (resistive, inductive, or capacitive) and ensure they fall within the relay’s specified ratings.

2. Poor Contact Protection – Inductive loads (e.g., motors, solenoids) generate back EMF, which can damage contacts over time.

  • Solution: Implement snubber circuits (RC networks) or flyback diodes to suppress voltage spikes.

3. Incorrect Coil Voltage Selection – Applying voltage outside the specified 24V DC ±10% range may result in unreliable operation or coil burnout.

  • Solution: Use a regulated power supply and verify voltage stability under load conditions.

4. Thermal Management Issues – High ambient temperatures (>70°C) can degrade relay performance.

  • Solution: Ensure proper ventilation and avoid mounting near heat-generating components.

5. Mechanical Vibration and Shock – Excessive vibration can cause contact chatter or misalignment.

  • Solution: Secure the relay with anti-vibration mounts or choose models with higher shock resistance if needed.

## Key Technical Considerations for Implementation

1. Contact Configuration – The MY2N-D2-GS features 2 Form C (SPDT) contacts, allowing versatile switching configurations. Ensure correct wiring for NO/NC operation.

2. Switching Speed and Life Expectancy – Mechanical life is rated at 10 million operations, while electrical life depends on load type (e.g., 100,000+ operations

Request Quotation

Part Number:
Quantity:
Target Price($USD):
Email:
Contact Person:
Additional Part Number
Quantity (Additional)
Special Requirements
Verification: =

Recommended Products

  • G6J-2FL-Y-DC12V ,12000,RELAY年份:18+

    G6J-2FL-Y-DC12V** is a **signal relay** manufactured by **OMRON**.

  • G5NB-1A-E-12VDC ,15083,

    G5NB-1A-E-12VDC** is a power relay manufactured by **OMRON**.

  • G2RL-24 DC12 ,6000,RELAY年份:17+/18+

    G2RL-24 DC12** is a general-purpose PCB relay manufactured by **OMRON**.

  • JAN2N918,MOTO,46,CAN3

    D2125AL,INTEL,46,CDIP


Sales Support

Our sales team is ready to assist with:

  • Fast quotation
  • Price Discount
  • Technical specifications
Contact sales