PartNumberManufactorQuantityAvailability
4800APC122Yes

APC part 4800 is a battery backup unit designed to provide reliable power protection for electronic devices.

The APC part 4800 is a battery backup unit designed to provide reliable power protection for electronic devices. Below are the specifications, descriptions, and features based on manufacturer details:

Specifications:

  • Model: APC Back-UPS 4800
  • Capacity: 4800VA / 2880W
  • Input Voltage: 120V
  • Output Voltage: 120V
  • Frequency: 50/60 Hz
  • Battery Type: Sealed Lead-Acid (SLA)
  • Battery Recharge Time: 8 hours (to 90% capacity)
  • Waveform: Simulated Sine Wave
  • Surge Energy Rating: 420 Joules
  • Transfer Time: 8-12 ms
  • Outlets:
  • Battery Backup & Surge Protection: 8 NEMA 5-15R
  • Surge Protection Only: 2 NEMA 5-15R
  • Communication Ports: USB, Serial (DB9)
  • Dimensions (H x W x D): 6.5" x 3.4" x 11.8"
  • Weight: 24.2 lbs (11 kg)

Descriptions:

The APC Back-UPS 4800 is an uninterruptible power supply (UPS) designed to protect connected equipment from power surges, outages, and fluctuations. It provides battery backup power to keep devices running during short outages and allows for safe shutdown during extended power failures.

Features:

  • Automatic Voltage Regulation (AVR): Corrects minor voltage fluctuations without using battery power.
  • Audible Alarms: Alerts users to power conditions such as outages or low battery.
  • LCD Display: Provides real-time status updates on power conditions and battery life.
  • PowerChute Software: Enables safe system shutdown and power management via connected devices.
  • Cold-Start Capability: Allows the UPS to power on connected devices even when mains power is unavailable.
  • Energy-Saving Design: Includes a master/controlled outlet feature to reduce standby power consumption.

This unit is suitable for home offices, workstations, and small business environments requiring reliable power protection.

# Technical Analysis of the APC 4800 Electronic Component

## Practical Application Scenarios

The APC 4800 is a high-performance electronic component designed for power distribution and management in critical infrastructure. Its primary applications include:

1. Data Centers: The 4800 provides reliable power conditioning and load balancing, ensuring uninterrupted operation of servers and networking equipment. Its scalable design supports modular expansion, making it suitable for both small server rooms and large-scale data centers.

2. Industrial Automation: In manufacturing environments, the 4800 mitigates voltage fluctuations and harmonic distortions, protecting sensitive PLCs and motor drives. Its rugged construction ensures durability in harsh conditions.

3. Telecommunications: The component’s high-efficiency power conversion minimizes energy loss in telecom base stations, while its fault-tolerant design reduces downtime during grid instability.

4. Healthcare Facilities: Hospitals leverage the 4800’s clean power output to safeguard medical imaging systems and life-support equipment from electrical noise and surges.

## Common Design-Phase Pitfalls and Avoidance Strategies

1. Inadequate Load Capacity Estimation:

  • *Pitfall:* Underestimating power requirements leads to overloading and premature failure.
  • *Solution:* Conduct a detailed load analysis, including peak and future expansion demands. Use APC’s sizing tools to validate capacity.

2. Improper Grounding and Shielding:

  • *Pitfall:* Poor grounding introduces noise, compromising signal integrity in sensitive applications.
  • *Solution:* Implement star grounding techniques and ensure shielded cabling for high-frequency circuits.

3. Thermal Management Oversights:

  • *Pitfall:* Inadequate ventilation causes overheating, reducing component lifespan.
  • *Solution:* Design for proper airflow, adhering to APC’s thermal derating guidelines. Consider active cooling in high-density installations.

4. Compatibility Issues with Legacy Systems:

  • *Pitfall:* Mismatched voltage or communication protocols disrupt integration.
  • *Solution:* Verify compatibility with existing infrastructure using APC’s interoperability matrices before deployment.

## Key Technical Considerations for Implementation

1. Input Voltage Range: Ensure the 4800’s input specifications align with local grid standards (e.g., 208V/240V for North America, 400V for Europe).

2. Efficiency Metrics: Evaluate the component’s efficiency curve to optimize performance at expected load levels (typically 90-95% efficiency at 50-75% load).

3. Protection Features: Prioritize models with integrated surge protection, short-circuit detection, and automatic bypass functionality for fault resilience.

4. Monitoring and Control: Leverage APC’s proprietary monitoring interfaces (e.g., Network Management Cards) for real-time diagnostics and remote management.

By addressing these factors, engineers can maximize the reliability and performance of the APC 4800 in diverse operational environments.

Request Quotation

Part Number:
Quantity:
Target Price($USD):
Email:
Contact Person:
Additional Part Number
Quantity (Additional)
Special Requirements
Verification: =

Recommended Products

  • KPS2801OCTLD ,19975,SSOP-4

    KPS2801OCTLD is a power supply module manufactured by COSMO.

  • AF93BC86-SI ,2415,SOP8

    AF93BC86-SI** is a serial EEPROM (Electrically Erasable Programmable Read-Only Memory) manufactured by **ABLIC Inc.

  • SN74LS299N ,250,DIP

    SN74LS299N** is a **8-bit universal shift/storage register** manufactured by **MOT/TI (Motorola/Texas Instruments)**.

  • LM2794TL,NS,12,BGA

    HD468B21P,HIT,12,DIP40


Sales Support

Our sales team is ready to assist with:

  • Fast quotation
  • Price Discount
  • Technical specifications
Contact sales